IP68 and a 1.5-meter drop claim describe different requirements and need separate evidence. Ingress classification concerns the enclosure. A drop claim needs its own conditions, such as the impact surface, orientations and post-test function checks. Neither phrase automatically proves the other.
Build two lines in the acceptance record
| Requirement | Evidence to request | Common gap |
|---|---|---|
| Enclosure protection | Exact model, applicable IP report and closure conditions | A family-level marketing image instead of a report |
| 1.5-meter drop | Height reference, surface, orientations, repetitions and sample configuration | Height alone, with no test method |
| Condition after impact | Defined functional checks and any separately performed ingress retest | Assuming a working screen proves unchanged sealing |
The IEC 60529 publication identifies the enclosure-classification framework. For an environmental test claim, the MIL-STD-810 record is useful background on tailoring. Neither source is a Phonemax model report.
Why the same height can produce different evidence
A phone tested in a case and one tested bare are different configurations. Likewise, a soft landing and a rigid impact surface are not interchangeable. A report should make these conditions explicit so procurement can compare the result with the expected handling risk.
Ask what “passed” meant. It might cover appearance, startup, communications or a longer functional sequence. Do not assume that every component was examined merely because the device powered on.
Write a requirement that can be reviewed
Use a statement such as: “Please supply evidence for the offered phone configuration under our specified drop conditions, with the post-test functional checks and any ingress retest listed separately.” Add the intended conditions to the request; do not copy an unexplained 1.5-meter headline into the purchase order as if its method were already agreed.
Can you drop and submerge the sample yourself?
Do not combine improvised destructive tests at work. Agree a test plan with the supplier or a suitable laboratory, including safe handling and what happens to tested samples. For daily use, follow the selected model's instructions and seek advice after damage.
Review the R4-T's listed features, then ask for model-specific protection evidence. This guide does not claim a verified 1.5-meter result for that model.




Efterlad en kommentar
Alle kommentarer er modereres, før de bliver offentliggjort.
'Denne side er beskyttet af hCaptcha, og hCaptchas Politik om beskyttelse af persondata og Servicevilkår er gældende.