A 0.05°C temperature difference equals 50mK, but a useful sensitivity comparison also needs the metric and test conditions. The current P20 Pro thermal graphic publishes NETD ≤50mK. This manufacturer entry is not a ±0.05°C temperature-accuracy guarantee.
Compare the same quantity
Confirm that each supplier is reporting NETD rather than a display increment or measurement error limit. FLIR describes NETD as a signal-to-noise measure of thermal sensitivity. Avoid ranking devices by numbers that describe different properties.
Ask for the conditions behind the value
- The evaluated camera configuration and lens.
- The target temperature and relevant camera settings.
- The test method and the supporting module or system report.
- Whether the figure applies to the delivered assembly rather than a different configuration.
Use a low-contrast task to assess usefulness
Ask the supplier to show the temperature differences your inspection must reveal, using a representative target and background. Keep the original output and note the conditions. A colourful palette or a high-contrast demonstration scene does not replace a sensitivity report.
Keep accuracy evidence separate
If a purchase also requires a defined temperature error limit, request that specification and its conditions independently. The accuracy-evidence guide covers that separate question.
Sources and limits
P20 Pro product specifications; FLIR: detector sensitivity. This article reports no original NETD, accuracy or clinical validation test.